Diagnostic Unit I plus User Manual (V2.1)
Brief
“I plus” increases to download and upload the characteristic program of MC (MC1、MC2、MC3) main board
based on original model, and saves the downloaded characteristic program of MC board into diagnostic unit I. It
has relative software which can backup downloaded characteristic programs in computers, or can upload
characteristic programs to diagnostic unit.
When do maintenance debugging on site, “I plus” is very convenient to solve many problems for long-service life
elevator projects due to characteristic program missing in main chipset, chipset damaged, or fake chipset etc…
and will not be worried about the trouble to replace main board but no chipset.
“I plus” needs to copy some parameters when replace MC board, it only takes few steps, and debugs other items:
well teach-in(AF10), rated speed(AF16), speed correction, external call scan(AF0C).
Usage Steps
 Keys and status switch operation.
“I plus” diagnostic unit appearance(Pic 1)
Here is a USB
port 
Page - 2 - of 8
 Pic 2
a. switch from normal debugging operation interface to parameter operation interface: in Pic 2, press “+”
“-” key at the same time until the first digit dot on the right light on, and diagnostic unit will switch into parameter
copy menu showed as pic 3. If it shows as pic 3, it enters into parameter operation interface.
 Pic 3
b. switch from parameter operation interface to normal debugging operation interface : In pic 3, press “+”
“-” key at the same time until the first digit dot on the right light on, the diagnostic unit back to normal debugging
status. (From pic 3 status to pic 2 status.)
c. enter into parameter operation interface as pic 3, press “+” or “-” key, can page up or down to check parameters.
“P - - 0”, “P - - 1”…… “P - - 9”. This device can save 0~9 parameters. If the display is dark, which means
the program is empty in this number, and it display light, it means the program is valid in this number.
 Sub-Menu explanations and operations for four parameters.
a. pause at “P--0” ( at 0 parameter), press “ENT” enter key, interface will switch from pic 3 to pic 4, it shows to
enter into the Number 0 parameter menu. “0-rt” : 0 means 0 parameters, “rt” is the abbreviation of return. If press
“ENT” key, the interface will switch back from pic 4 to pic 3.
 Pic 4
b. press “-” key in pic 4, will show pic 5, “0-id” shows the ID for the number 0 saved parameter (normally, it
refers to the characteristic number of elevator ). Press “ENT” key under pic 5, it will rolling display saved
parameters ID. If the display color is dark, it means no saved parameters; it is no valid to press “ENT”, no display
parameter ID.
 Pic 5
c. press “-” key in Pic 5 , will show pic 6, and press twice “ENT” key , it will download MC board parameters into
diagnostic unit I plus. (“0-dn” , “dn” is the abbreviation of download). 
Page - 3 - of 8
 Pic 6
d. Press “-” in pic 6 to show Pic 7, and press twice “ENT” key will upload parameters from diagnostic unit to
main board and saved. If display color is dark ,it means don’t have valid parameters, and will not upload
parameters and save.
 Pic 7
 Download parameters (download parameters from main board to
diagnostic unit and save)
Change page to this interface, “0-DN’, DN is for download, and press twice “ENT” key, will download
parameters as below pictures.
When downloading, the number 3. 4 digit dot on the bottom right is blinking.
If finish parameter download, will display “SUCC” , it means to save parameters successful. 
Page - 4 - of 8
 Parameters upload. (upload parameters from diagnostic unit to main
board and save) -Must be in the inspection state
Change page to this interface, “0-UP”, it means upload, press twice “ENT” key, and will upload parameters
from diagnostic unit to main board as below pictures.
When uploading, the number 3. 4 digit dot on the bottom right is blinking
Display “SAVE ”, it means the parameters has been received successfully, and main board is saving parameters.
Please don’t touch the communication cable and diagnostic unit at this time.
It will display “SUCC” when parameters is uploaded and saved successfully. At the same time, please power off
main power supply and restart elevator main board.
 Supplementary explanation about upload and download from main
board. 
Page - 5 - of 8
If shows “E-XX” , it means the relative operation is error, Please check the main board status, communication
cable etc…
Explanations of Error codes :
E—10 error from downloading data
E—11 error from downloading data timeout
E—12 An error occurred while downloading data and fail to save.
E—00 invalid uploaded data
E—01 error from uploading data
E—02 error from uploading data timeout
E—03 version error while uploading data
E—04 error from uploading data, please restart main board
E—05 error from saving codes while uploading data.
E—06 error from saving operation while uploading data
E—20 unknown error
 Backup characteristic program to computer
 Restore characteristic program to diagnostic unit
 The code meaning when copy parameters from diagnostic unit.
Software Operations:
1. upload file from computer to diagnostic unit
1
2. open serial
port
3. select needed
spec upload to
diagnostic unit
4. select to save
specs
1. select COM
port
5. click to upload
specs to diagnostic
unit
6. uploaded spec to diagnostic
unit, successfully 
Page - 6 - of 8
2. download spec from diagnostic unit to computer
3.Illustration for spec modification
2. Input your modified spec address
and click enter to save, and select
it, the value for this address will be
changed automatically. Click”
modify” button, will show the
modified value.
3. click save to
take effect.
upline is original
value
downline is
modified value
1. upload or open the spec file, click
“spec” in menu, and select “spec modify”
1. select COM
port
2. open
serial port
3. select program Number for
needed backup to computer
4. click to download
spec
5、download spec successfully
6. click to save,
and select the
saved route.
Done. 
Page - 7 - of 8
4、data cable connection
5. the accessories for connector changes from USB to RS232 serial port.
this connector is only
for diagnostic unit,
forbid connecting with
USB of computer.
The short-line USB
connector, is 5V power
supply, when diagnostic unit
needs 5V power supply, it can
connect computer USB ,
mobile phone charges or
power charger. The short-line
USB connector is only for
power supply
9-pin RS232 serial
port is for the
connection with board
port of elevator’s MC
board or RS232 of
computer.
2 – RXD
3 – TXD
5 – GND
9 – 5V DC 
Page - 8 - of 8
Note: when diagnostic unit connects with computer, if computer is not with RS232 serial connector, will need this
accessories.
6. Distinguish
RS232 


文件下載:點擊下載Diagnostic unit I plus User Manual_3-E (點擊查看下載口令
    下載申明:(1)倍加信梯控提供的Diagnostic unit I plus User Manual_3-E資料來源于網絡收集整理,并免費提供下載Diagnostic unit I plus User Manual_3-E不收取任何費用,若發現您的權益受到侵害,請立即聯系我們,我們會立即刪除Diagnostic unit I plus User Manual_3-E資料。(2)倍加信梯控提供的Diagnostic unit I plus User Manual_3-E資料僅供用戶學習和參考,用戶如果使用下載的Diagnostic unit I plus User Manual_3-E資料造成任何損失與倍加信無關,Diagnostic unit I plus User Manual_3-E資料最終以版權廠家提供原廠資料為準。(3)倍加信梯控免費提供大量蒂森電梯技術資料下載,歡迎收藏本站,底部右下角提供了搜索功能,倍加信人臉識別梯控、IC刷卡梯控、二維碼梯控、指紋識別梯控、語音梯控、CPU梯控、ID卡梯控、手機乘梯、機器人乘梯等廣泛應用于蒂森電梯,歡迎掃碼二維碼加個微信咨詢或備用,再次感謝您在倍加信梯控免費下載蒂森電梯Diagnostic unit I plus User Manual_3-E。

主站蜘蛛池模板: 久久91| 国产亚洲精品麻豆一区二区 | 国产精品第8页 | 午夜国产福利 | 精品国产90后在线观看 | 奇米影| 91蝌蚪在线播放 | 亚洲精品欧美在线 | 一级成人毛片免费观看欧美 | 国产大片免费观看中文字幕 | 日韩美女强理论片 | 青草青草久热精品视频99 | 影音先锋在线亚洲精品推荐 | 免费播放欧美毛片欧美a | 欧美第一精品 | 亚洲十欧美十日韩十国产 | 日本成人不卡视频 | 爱婷婷网站在线观看 | 日产精品一区二区 | 欧美 日韩 中文字幕 | 久久精品中文字幕免费 | 久热精品在线 | 亚洲精品色一区二区三区 | 日韩一区二区三区中文字幕 | 久久久久久免费精品视频 | 国产高清国内精品福利色噜噜 | 成年人免费网址 | 牛人盗摄一区二区三区视频 | 国产高清在线精品一区a | 高清毛片在线看高清 | 中文字幕在线视频在线看 | 国产一区视频在线播放 | 久久国产乱子伦精品免费一 | 偶偶福利视频 | 欧美日比 | 波多野结衣中文字幕一区 | 色多网站免费视频 | 国产成人一区二区在线不卡 | 亚洲香蕉毛片久久网站老妇人 | 国产在线观看一区精品 | 日韩一区三区 |